Industrial
Quick Details Overview The ZWM3C33 series product is a double-conversion online three-phase power frequency UPS system u
Description
Basic Info.
Model NO. | ZWM3C33 10~200KS |
Standby UPS | Sine Wave Output UPS |
Output Capacity | 10kVA-200kVA |
Transport Package | The Wooden Case |
Trademark | zhuowoma |
Origin | China |
HS Code | 8537209000 |
Production Capacity | 10000 Pieces / Year |
Product Description
Quick DetailsModel No. | 10K | 15K | 20K | 30K | 40K | 60K | 80K | 100K | 120K | 160K | 200K | ||
Power rating | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA | ||
8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW | 128KW | 160KW | |||
Mains input | Rated voltage | 3x380/400V(3Ph+N) | |||||||||||
Rated frequency | 50Hz/60Hz | ||||||||||||
Voltage range | 165V~280V(Ph-N)/285V~485V(Ph-Ph) | ||||||||||||
Frequency range | [email protected];[email protected] | ||||||||||||
Rated current per phase | 20A | 30A | 38A | 55A | 72A | 108A | 130A | 160A | 200A | 277A | 330A | ||
Inverter output | Wave form | Pure sine wave | |||||||||||
Voltage range | 3x380/400V(3Ph+N) | ||||||||||||
Error range | ±1%(balanced load) | ||||||||||||
Rated frequency | 50/60Hz±1% | ||||||||||||
Harmonic distortion | Linear load<2%; PF0.8 nonlinear load<5% | ||||||||||||
Overload capacity | 110%~150%10min~60s;>160%200ms | ||||||||||||
Efficiency | >90% | ||||||||||||
Battery parameters | Quantity | 29/30/31/32PCS(12V in series) | |||||||||||
Rated voltage | 384VDC | ||||||||||||
Charge current | Default 10A;Maximum = capacity (KW) / total battery voltage (real-time voltage); The maximum current does not exceed 40A | Default 10A; maximum 40A; full load maximum current 5A | |||||||||||
Float voltage | 13.5VDC/PCS(12V) | ||||||||||||
High voltage protection | 14.5VDC/PCS(12V) | ||||||||||||
Static bypass | Rated voltage | 3x380/400V(3Ph+N) | |||||||||||
Rated frequency | 50/60Hz | ||||||||||||
Voltage range | 176V~264V(Ph-N)/304V~456V(Ph-Ph) | ||||||||||||
Frequency range | [email protected];[email protected] | ||||||||||||
Switching time | 0s | ||||||||||||
Overload capacity | 150%~180%1h~30s;180%~>200%30s~200ms | ||||||||||||
ECO mode(default off) | Rated voltage | 3x380/400V(3Ph+N) | |||||||||||
Rated frequency | 50/60Hz | ||||||||||||
Voltage range | 176V~264V(Ph-N)/304V~456V(Ph-Ph) | ||||||||||||
Frequency range | [email protected];[email protected] | ||||||||||||
Switching time | <10ms |
Overview
The ZWM3C33 series product is a double-conversion online three-phase power frequency UPS system under DSP and full digital control technology. It has outstanding high stability and high reliability. The power frequency transformer will interfere with the surge spikes of the mains and the load. The impact is effectively suppressed and isolated, and the harmonic distortion of the load current can be greatly improved, so that the load and the UPS are in a better state of coordination. ZWM3C33 series products have powerful parallel redundancy features, good remote monitoring and human-machine interface interaction, and are very suitable for use in medium and large data centers, precision equipment, telecommunications, and medical industries.
Application
Our UPS systems are suitable for a wide range of critical applications where continuous, clean, and stable power is essential.Product Picture
Features
• Available from 10 to 200 kVA• Power output factor 0.8• Parallel Redundancy up to 4 units• Front maintenance design•LCD display and LED status indicators•Online double-conversion under DSP full digital control technology
Advantages
1.Built-in isolation transformer protects user equipment.
2.Parallel expansion as your business grows and consequently saves initial investment(up to 4 units).
3.Variable network communication interface for remote control management.
4. Intelligent battery management to prolong battery lifecycle.
With constant charge, floating charge and equalization, as well as temperature compensation; Flexible battery configuration: the number of battery cells per group can be set on the operation panel to 32/31/30/29.
5.Economy mode saves energy and operating cost.
The efficiency of the whole machine is as high as 90%; in ECO operation mode, its energy conversion efficiency is as high as 98%.
Package
Company Information
Zhejiang Zhuowoma Electric Technology Co.,Ltd. is a diversified enterprise specialized in the development, manufacturing, sales and service of high-voltage power transmission and distribution. Factory have passed the IS09001:2000 quality management system certification and products have access to the production licence with"CCC" certification.
FAQ
Q:Why is a UPS needed?
A:Unsteady power quality can affect the normal operation of a computer. A UPS not only provides immediate power in case of blackout, but also provides stable and clean power under normal conditions. It improves the incoming power by regulation and filtration and also suppresses spikes caused by lightning. A UPS, is like a personal insurance policy
and protects your computer equipment against power risks.
Q:How is the capacity of a UPS determined?
A:Most commercially available UPS now express their capacity as VA. V stands for voltage and A for current in amps. In short, VA equals the power and capacity of a UPS. For example, a UPS of 500VA capacity with an output of 110V will provide a maximum current of 4.55A and more than this will lead to overload. The unit of power can be expressed in Watts. While the Watt indicates active power, VA indicates apparent power and Watt equals VA multiplied by the power factor (VA × pf = Watt). There is no common criterion for power factor (pf). Generally a value of between 0.6 and 0.9 is acceptable while a value of 0.5 may represent poor design. Pay attention to this value when purchasing a UPS. A high power factor implies better utilization and more economical use of power.
Q:Where can an appropriate UPS be bought?
A:1. Learn about the applicability of each type of UPS.
2. Appraise your needs for power quality.
3. Learn the required UPS capacity and appraise the total capacity required for future expansion.
Q:Is a UPS really needed in places with very few black-outs?
A:Statistics indicate that black-outs are a minor power issue. Other, not so obvious power issues, like over-voltage, under-voltage and surges are the major ones. In addition to providing extended power for long stretches, a UPS is designed to provide customers with critical total power protection against voltage drift, surges, high frequency interference, and any other kind of power failure and drift.
Q:How long should the UPS provide power?
A:The single most important function of a UPS is to provide adequate backup power for the equipment load. The time a UPS should provide power should be long enough for users to finish running procedures in case of power failure. In general, 5 to 10 minutes should be enough. If longer than this is required, you can purchase a UPS that includes an external battery cabinet(s) that will increase the UPS backup time.
Prev: Factory Supply 3.2V 32650 32700 6000mAh LiFePO4 Battery for EV Storage Uav Digital Devices
Next: 25.2V 7s 5000mAh Lipo Battery Aircraft Model Battery for Uav or Drone
Our Contact
Send now