banner

Products

Industrial

Industrial

Quick Details Overview The ZWM3C33 series product is a double-conversion online three-phase power frequency UPS system u
SHARE

Description

Basic Info.
Model NO. ZWM3C33 10~200KS
Standby UPS Sine Wave Output UPS
Output Capacity 10kVA-200kVA
Transport Package The Wooden Case
Trademark zhuowoma
Origin China
HS Code 8537209000
Production Capacity 10000 Pieces / Year
Product Description
Quick Details
Model No.10K15K20K30K40K60K80K100K120K160K200K
Power rating10KVA15KVA20KVA30KVA40KVA60KVA80KVA100KVA120KVA160KVA200KVA
8KW12KW16KW24KW32KW48KW64KW80KW96KW128KW160KW

Mains input
Rated voltage3x380/400V(3Ph+N)
Rated frequency50Hz/60Hz
Voltage range165V~280V(Ph-N)/285V~485V(Ph-Ph)
Frequency range[email protected];[email protected]
Rated current per phase20A30A38A55A72A108A130A160A200A277A330A

Inverter output
Wave formPure sine wave
Voltage range3x380/400V(3Ph+N)
Error range±1%(balanced load)
Rated frequency50/60Hz±1%
Harmonic distortionLinear load<2%; PF0.8 nonlinear load<5%
Overload capacity110%~150%10min~60s;>160%200ms
Efficiency>90%

Battery parameters
Quantity29/30/31/32PCS(12V in series)
Rated voltage384VDC
Charge currentDefault 10A;Maximum = capacity (KW) / total battery voltage (real-time voltage); The maximum current does not exceed 40ADefault 10A; maximum 40A; full load maximum current 5A
Float voltage13.5VDC/PCS(12V)
High voltage protection14.5VDC/PCS(12V)

Static bypass
Rated voltage3x380/400V(3Ph+N)
Rated frequency50/60Hz
Voltage range176V~264V(Ph-N)/304V~456V(Ph-Ph)
Frequency range[email protected];[email protected]
Switching time0s
Overload capacity150%~180%1h~30s;180%~>200%30s~200ms

ECO mode(default off)
Rated voltage3x380/400V(3Ph+N)
Rated frequency50/60Hz
Voltage range176V~264V(Ph-N)/304V~456V(Ph-Ph)
Frequency range[email protected];[email protected]
Switching time<10ms

Overview
The ZWM3C33 series product is a double-conversion online three-phase power frequency UPS system under DSP and full digital control technology. It has outstanding high stability and high reliability. The power frequency transformer will interfere with the surge spikes of the mains and the load. The impact is effectively suppressed and isolated, and the harmonic distortion of the load current can be greatly improved, so that the load and the UPS are in a better state of coordination. ZWM3C33 series products have powerful parallel redundancy features, good remote monitoring and human-machine interface interaction, and are very suitable for use in medium and large data centers, precision equipment, telecommunications, and medical industries.
Application
Our UPS systems are suitable for a wide range of critical applications where continuous, clean, and stable power is essential.Product Picture

Industrial-Grade 10kVA-200kVA Three Phase Online Double Conversion UPS

Features
• Available from 10 to 200 kVA• Power output factor 0.8• Parallel Redundancy up to 4 units• Front maintenance design•LCD display and LED status indicators•Online double-conversion under DSP full digital control technology
Advantages
1.Built-in isolation transformer protects user equipment.

Industrial-Grade 10kVA-200kVA Three Phase Online Double Conversion UPS


2.Parallel expansion as your business grows and consequently saves initial investment(up to 4 units).

Industrial-Grade 10kVA-200kVA Three Phase Online Double Conversion UPS


3.Variable network communication interface for remote control management.

Industrial-Grade 10kVA-200kVA Three Phase Online Double Conversion UPS

4. Intelligent battery management to prolong battery lifecycle.
With constant charge, floating charge and equalization, as well as temperature compensation; Flexible battery configuration: the number of battery cells per group can be set on the operation panel to 32/31/30/29.
5.Economy mode saves energy and operating cost.
The efficiency of the whole machine is as high as 90%; in ECO operation mode, its energy conversion efficiency is as high as 98%.
Package

Industrial-Grade 10kVA-200kVA Three Phase Online Double Conversion UPS

Company Information
Zhejiang Zhuowoma Electric Technology Co.,Ltd. is a diversified enterprise specialized in the development, manufacturing, sales and service of high-voltage power transmission and distribution. Factory have passed the IS09001:2000 quality management system certification and products have access to the production licence with"CCC" certification.

FAQ
Q:Why is a UPS needed?
A:Unsteady power quality can affect the normal operation of a computer. A UPS not only provides immediate power in case of blackout, but also provides stable and clean power under normal conditions. It improves the incoming power by regulation and filtration and also suppresses spikes caused by lightning. A UPS, is like a personal insurance policy
and protects your computer equipment against power risks.
Q:How is the capacity of a UPS determined?
A:Most commercially available UPS now express their capacity as VA. V stands for voltage and A for current in amps. In short, VA equals the power and capacity of a UPS. For example, a UPS of 500VA capacity with an output of 110V will provide a maximum current of 4.55A and more than this will lead to overload. The unit of power can be expressed in Watts. While the Watt indicates active power, VA indicates apparent power and Watt equals VA multiplied by the power factor (VA × pf = Watt). There is no common criterion for power factor (pf). Generally a value of between 0.6 and 0.9 is acceptable while a value of 0.5 may represent poor design. Pay attention to this value when purchasing a UPS. A high power factor implies better utilization and more economical use of power.
Q:Where can an appropriate UPS be bought?
A:1. Learn about the applicability of each type of UPS.
2. Appraise your needs for power quality.
3. Learn the required UPS capacity and appraise the total capacity required for future expansion.
Q:Is a UPS really needed in places with very few black-outs?
A:Statistics indicate that black-outs are a minor power issue. Other, not so obvious power issues, like over-voltage, under-voltage and surges are the major ones. In addition to providing extended power for long stretches, a UPS is designed to provide customers with critical total power protection against voltage drift, surges, high frequency interference, and any other kind of power failure and drift.
Q:How long should the UPS provide power?
A:The single most important function of a UPS is to provide adequate backup power for the equipment load. The time a UPS should provide power should be long enough for users to finish running procedures in case of power failure. In general, 5 to 10 minutes should be enough. If longer than this is required, you can purchase a UPS that includes an external battery cabinet(s) that will increase the UPS backup time.

Our Contact